School backup diesel
Voltage: 220V–480V (customizable)
Speed(R.P.M):1500/1800
Frequency(HZ):50HZ/60HZ
Noise Level: 65–75 dB(A) at 7 meters
Dimensions: Compact to industrial-scale designs
Phase:Single/Three phaseType:Silent/Open Frame
Engine Type:Two/Four cylinder
Cooling System: Radiator-based or closed-loop
Starting Method:Electric starting
Customization: OEM/ODM
Certifications: CE, ISO8528, GB/T 2820-97
- Product Description
JLMECH:Your Trusted School backup diesel Partner
As a specialized manufacturer with extensive experience in institutional power solutions, we provide reliable School backup diesel engineered to maintain uninterrupted operations during power outages. Our technical team specializes in configuring school backup diesel generators that meet the unique requirements of educational facilities, ensuring student safety, operational continuity, and compliance with educational institution regulations.
Critical Power Requirements for Educational Institutions
Life Safety Systems
Uninterrupted emergency lighting for corridors and exit routes
Continuous operation of fire alarm and detection systems
Functional PA systems for emergency announcements
Access control and security system maintenance
Infrastructure Continuity
HVAC systems for climate control in classrooms and facilities
Operational water pumps and sanitation systems
Kitchen equipment for meal service continuity
Critical computer servers and data protection
Educational Program Protection
Science laboratory equipment requiring constant power
Computer labs and educational technology systems
Library systems and resource centers
Administrative operations and communication systems

Specifications
| Unit model | Power(KW) | Power(KVA) | current(A) | Engine model | Cylinder | Bore×Stroke | Displacement | Lube oil | fuel consumption ( g/kw.h) | Size(mm) | Weight(Kg) |
| JL-24GF | 24 | 30 | 43.2 | 4B3.9-G2 | 4 | 102*120 | 3.9 | 11 | 208 | 1620*710*1100 | 710 |
| JL-30GF | 30 | 37.5 | 54 | 4BT3.9-G2 | 4 | 102*120 | 3.9 | 11 | 208 | 700*710*1110 | 800 |
| JL-40GF | 40 | 50 | 72 | 4BTA3.9-G2 | 4 | 102*120 | 3.9 | 11 | 210 | 1800*800*1200 | 920 |
| JL-50GF | 50 | 62.5 | 90 | 4BTA3.9-G2 | 4 | 102*120 | 3.9 | 11 | 210 | 800*800*1200 | 950 |
| JL-64GF | 64 | 80 | 115.2 | 4BTA3.9-G11 | 4 | 102*120 | 3.9 | 11 | 210 | 1850*800*1200 | 1000 |
| JL-80GF | B0 | 100 | 144 | 6BT5.9-G2 | 6 | 102*120 | 5.9 | 16 | 210 | 2200*800*1200 | 1250 |
| JL-100GF | 100 | 125 | 180 | 6BTA5.9-G2 | 6 | 102*120 | 5.9 | 20 | 207 | 2200*800*1200 | 1300 |
| JL-120GF | 120 | 150 | 216 | 6BTAA5.9-G2 | 6 | 102*120 | 5.9 | 24 | 207 | 2250*800*1200 | 1350 |
| JL-132GF | 132 | 165 | 237.6 | 6BTAA5.9-G12 | 6 | 102*120 | 5.9 | 24 | 207 | 2300*820*1300 | 1350 |
| JL-150GF | 150 | 187.5 | 270 | 6CTA8.3-G2 | 6 | 114*135 | 8.3 | 24 | 207 | 2300*820*1330 | 1600 |
| JL-18DGF | 180 | 225 | 324 | 6CTAA8.3-G2 | 6 | 114*135 | 8.3 | 24 | 207 | 2550*1050*1480 | 1700 |
| JL-200GF | 200 | 250 | 360 | 6LTAA8.9-G2 | 6 | 114*145 | 8.9 | 28 | 207 | 2550*1050*1500 | 2000 |
| JL-220GF | 220 | 275 | 396 | 6LTAA8.9-G3 | 6 | 114*145 | 8.9 | 28 | 203 | 2550*1050*1500 | 2000 |
| JL-400GF | 400 | 500 | 720 | QSZ13-G2 | 6 | 130*163 | 13 | 28 | 201 | 3150*1360*1800 | 3200 |
| JL-450GF | 450 | 562.5 | 810 | QsZ13-G3 | 6 | 130*163 | 13 | 28 | 201 | 3160*1360*1800 | 3300 |
| JL-500GF | 500 | 625 | 900 | KTA19-G8 | 6 | 159*159 | 19 | 50 | 206 | 3500*1380*1800 | 4000 |
| JL-600GF | 600 | 750 | 1080 | KT38-GA | 12 | 159*159 | 38 | 100 | 206 | 4350*1800*2350 | 7000 |
| JL-700GF | 700 | 875 | 1260 | KTA38-G2B | 12 | 159*159 | 38 | 100 | 206 | 4350*1800*2350 | 7500 |
| JL-800GF | 800 | 1000 | 1440 | KTA38-G2A | 12 | 159*159 | 38 | 100 | 206 | 4350*1800*2350 | 7500 |
| JL-900GF | 9D0 | 1125 | 1620 | KTA38-G9 | 12 | 159*159 | 38 | 135 | 208 | 4450*1800*2350 | 8200 |
| JL-1000GF | 1000 | 1250 | 1800 | KTA38-G9 | 12 | 159*159 | 38 | 135 | 208 | 4450*1850*2350 | 8200 |
| JL-1100GF | 1100 | 1375 | 1980 | KTA50-G3 | 16 | 159*159 | 50 | 177 | 205 | 5000*2040*2430 | 9500 |
| JL-1200GF | 1200 | 1500 | 2160 | KTA50-G8 | 16 | 159*159 | 50 | 204 | 205 | 5350*2110*2500 | 10000 |
The rotational speed in the above School backup diesel technical parameters is 1500 RPM, the frequency is 50 Hz, the rated voltage is 400/230V, the power factor is 0.8, and the wiring method is three-phase four-wire. The 60 Hz generator sets and generator brands can be customized according to the special needs of customers. This parameter table is for reference only. For details, please contact our customer service.
Why Choose US?
- OEM Expertise: As an authorized partner for Cummins, we adhere to strict quality protocols.
- Custom Solutions: Tailor voltage, fuel efficiency, and control systems to your project.
- Global Support: 26 overseas offices in Africa and Southeast Asia ensure rapid technical assistance.
- Cost Efficiency: Optimized TCO (total cost of ownership) through energy-saving designs and extended service intervals.
Packaging and Delivery

Units are securely packaged in weatherproof crates with anti-corrosion treatments. Global shipping via sea/air freight available.
Company Profile

Wuhan Jlmech Co., Ltd. operates 11 branches across China and employs 126 technical experts, including 27 senior engineers. Our 35,000m² facility features automated assembly lines and rigorous testing systems, ensuring every School backup diesel meets international standards.
Factory After-Sales Service
Enjoy 24/7 technical support, a 2-year warranty, and guaranteed 48-hour spare parts delivery worldwide.
Certification

ISO9001, ISO14001, CE, and GS-certified manufacturing processes.
Exhibitions

We showcase innovations at PowerGen International, Middle East Energy, and regional trade shows.
FAQ
Q: Can I request a generator customized for high-altitude operations?
A: Yes! Our engineers adjust air-fuel ratios and cooling systems for performance at elevations up to 4,500 meters.
Q: What's the lead time for bulk orders?
A: 15–30 days, depending on specifications. Urgent orders prioritized.
Q: Do you offer financing options?
A: Flexible payment terms and leasing plans are available for large-scale procurement.
Q: How do you ensure compliance with local emissions laws?
A: Each School backup diesel is pre-tested for regional regulatory alignment.
Power Your Projects with Confidence
Whether you're managing a mining operation in Africa or a data center in Southeast Asia, our School backup diesel guarantees reliability. Contact us at skala@whjlmech.com to discuss your requirements or request a free quote.