fuel consumption of diesel generator
AC Output(KW):120KW/150KVA
Rated AC Voltage(V):400
Frequency(HZ):50
Engine Speed(R.P.M):1500
Phase:Three Phase
Type:Silent/Open Frame
Engine Type:3/4/6/8/12/16 cylinder
Cooling Method: Water Cooling
Starting Method:Electric Starting
Customization: OEM/ODM
Certificates: CE/Euro 5/EPA/CARB
- Product Description
Fuel Consumption of Diesel Generator: Optimizing Efficiency for Global Operations
In the realm of industrial power generation, the fuel consumption of diesel generator stands as a pivotal metric for operational efficiency and cost management. Wuhan JLMECH Co., Ltd. specializes in engineering diesel generators that redefine fuel economy without compromising performance, making us a trusted partner for clients worldwide. Our solutions, designed with advanced combustion technology and rigorous testing, address the core challenge of minimizing fuel consumption while ensuring reliable power output. Whether for emergency backup in hospitals, continuous operation in mining sites, or temporary power at construction projects, the fuel consumption of our diesel generators is optimized to meet the diverse needs of global industries.
The Core Features of Low Fuel Consumption Diesel Generators
1.Advanced Combustion Systems for Minimal Fuel Waste
The fuel consumption of diesel generator is fundamentally driven by our proprietary Fastram combustion technology, which ensures complete fuel atomization and uniform distribution. This system, paired with high-pressure common rail fuel injection, reduces fuel consumption by up to 15% compared to conventional models. For instance, our 150kVA Perkins diesel generator achieves a fuel consumption rate of 206g/kWh at 75% load, a testament to its efficiency. The design minimizes unburned fuel emissions, aligning with both environmental standards and cost-saving objectives.
2. Intelligent Load Response Technology
Our generators feature dynamic load sensing that adjusts fuel delivery in real-time, preventing excessive consumption during load fluctuations. This technology is critical for applications where load demands vary, such as data centers or manufacturing plants. By rapidly optimizing fuel input, our systems maintain stable power output while keeping fuel consumption at optimal levels, reducing operational costs over the generator’s lifespan.
3. Compliance with Global Efficiency Standards
All models undergo rigorous testing to meet international benchmarks for fuel efficiency, including EPA Tier 3, Euro 5, and ISO 8528-13. These certifications validate that the fuel consumption of our diesel generators complies with the strictest environmental and performance requirements, ensuring clients receive reliable, efficient, and sustainable power solutions.
Specifications
Genset model | Power(kw) | current | Engine model | Cylinders | Bore*stroke | Displacement | Oil capacity | Fuel consumption rate | Dimensionsmm | Gross weight | |
KW | KVA | A | mm | L | L | g/kw.h | L×W×H | KG | |||
JL-8GF | 8 | 10 | 14.4 | 403D-11G | 3 | 77*81 | 1.13 | 4.9 | 252 | 1200×700×1100 | 300 |
JL-11GF | 11 | 13.75 | 19.8 | 403D-15G | 3 | 84*90 | 1.49 | 6.5 | 247 | 1250×700×1100 | 350 |
JL-16GF | 16 | 20 | 28.8 | 404D-22G | 4 | 84*100 | 2.2 | 11.2 | 245 | 1500×730×1300 | 500 |
JL-22GF | 22 | 27.5 | 39.6 | 404D-22TG | 4 | 84*100 | 2.2 | 11.2 | 245 | 1600×730×1300 | 550 |
JL-24GF | 24 | 30 | 43.2 | 1103A-33G | 3 | 105*127 | 3.3 | 8.3 | 211 | 1770×750×1600 | 800 |
JL-36GF | 36 | 45 | 64.8 | 1103A-33TG1 | 3 | 105*127 | 3.3 | 8.3 | 211 | 2050×750×1600 | 920 |
JL-48GF | 48 | 60 | 86.4 | 1103A-33TG2 | 3 | 105*127 | 3.3 | 8.3 | 215 | 2200×750×1600 | 1050 |
JL-52GF | 52 | 65 | 93.6 | 1104A-44TG1 | 4 | 105*127 | 4.4 | 8.3 | 208 | 2250×750×1600 | 1100 |
JL-64GF | 64 | 80 | 115.2 | 1104A-44TG2 | 4 | 105*127 | 4.4 | 8.3 | 208 | 2300×750×1600 | 1150 |
JL-80GF | 80 | 100 | 144 | 1104C-44TAG2 | 4 | 100*127 | 4.4 | 8.3 | 208 | 2480×760×1600 | 1250 |
JL-110GF | 110 | 137.5 | 198 | 1006TAG | 6 | 100*127 | 6 | 19 | 208 | 2600×760×1600 | 1400 |
JL-120GF | 120 | 150 | 216 | 1006TAG2 | 6 | 100*127 | 6 | 19 | 208 | 2650×760×1600 | 1450 |
JL-140GF | 140 | 175 | 252 | 1106C-E66TAG4 | 6 | 105*127 | 6.6 | 19 | 205 | 2700×900×1600 | 1700 |
JL-160GF | 160 | 200 | 288 | 1306C-E87TAG3 | 6 | 116*136 | 8.7 | 26.4 | 201 | 3000×1000×1700 | 2100 |
JL-180GF | 180 | 225 | 324 | 1306C-E87 TAG4 | 6 | 116*136 | 8.7 | 26.4 | 201 | 3000×1000×1700 | 2100 |
JL-200GF | 200 | 250 | 360 | 1306C-E87 TAG6 | 6 | 116*136 | 8.7 | 26.4 | 201 | 3100×1000×1700 | 2150 |
JL-280GF | 280 | 350 | 504 | 2206C-E13TAG2 | 6 | 130*157 | 12.5 | 40 | 209 | 3600×1200×2000 | 3200 |
JL-320GF | 320 | 400 | 576 | 2206C- E13TAG3 | 6 | 130*157 | 12.5 | 40 | 206 | 3650×1200×2000 | 3300 |
JL-360GF | 360 | 450 | 648 | 2506C-E15TAG1 | 6 | 137*171 | 15.2 | 53 | 211 | 4000×1200×2100 | 3700 |
JL-400GF | 400 | 500 | 720 | 2506C-E15TAG2 | 6 | 137*171 | 15.2 | 53 | 211 | 4050×1200×2100 | 3760 |
JL-480GF | 480 | 600 | 864 | 2806A-E18TAG1A | 6 | 145*183 | 18.1 | 55 | 203 | 4100×1600×2200 | 4600 |
JL-500GF | 500 | 625 | 900 | 2806A-E18TAG2 | 6 | 145*183 | 18.1 | 55 | 202 | 4200×1600×2200 | 4800 |
JL-580GF | 580 | 725 | 1044 | 4006-23TAG2A | 6 | 160*190 | 22.9 | 113 | 209 | 4500×1800×2300 | 5500 |
JL-640GF | 640 | 800 | 1152 | 4006-23TAG3A | 6 | 160*190 | 22.9 | 113 | 209 | 4600×1800×2300 | 6000 |
JL-720GF | 720 | 900 | 1296 | 4008TAG2A | 8 | 160*190 | 30.5 | 153 | 206 | 4800×2100×2500 | 7700 |
JL-800GF | 800 | 1000 | 1440 | 4008TAG2A | 8 | 160*190 | 30.5 | 153 | 206 | 4900×2100×2500 | 8000 |
JL-1000GF | 1000 | 1250 | 1800 | 4012-46TWG2A | 12 | 160*190 | 45.8 | 159 | 212 | 5300×2200×2600 | 10000 |
JL-1200GF | 1200 | 1500 | 2160 | 4012-46TAG2A | 12 | 160*190 | 45.8 | 159 | 212 | 5400×2200×2600 | 11000 |
JL-1400GF | 1400 | 1750 | 2520 | 4016TAG | 16 | 160*190 | 61.1 | 214 | 205 | 5700×2800×3100 | 13500 |
JL-1600GF | 1600 | 2000 | 2880 | 4016TAG2A | 16 | 160*190 | 61.1 | 214 | 208 | 5800×2800×3100 | 14000 |
JL-1800GF | 1800 | 2250 | 3240 | 4016-61TRG3 | 16 | 160*190 | 61.1 | 214 | 205 | 5900×2800×3100 | 15700 |
The Perkins series generator sets have a frequency of 50HZ, a rotational speed of 1500rpm, a voltage of 400V, a power factor of 0.8 (lagging), and adopt a three-phase four-wire system. If you need models with other special requirements, please contact us and we will provide the relevant parameters separately.
Perkins diesel generator sets feature stable power output and high operating efficiency. Its unique Fastram combustion system, combined with advanced fuel injection technology, enables the fuel to burn fully, effectively reducing fuel consumption. It can quickly respond to load changes. When the load suddenly increases or decreases, it can rapidly adjust the output power to ensure the stability and reliability of power supply and minimize the impact on electrical equipment.
Why Choose US?
- Proven Expertise: 52 engineers across 3 R&D centers ensure cutting-edge design.
- Global Support: 26 overseas offices in Africa/Asia provide rapid spare parts and repairs.
- OEM Partnerships: Trusted by Perkins, Cummins, and MTU for precision manufacturing.
- 2-Year Warranty: Comprehensive coverage for mechanical and electrical components.
Packaging and Delivery
Units are crated in anti-corrosion wooden frames and delivered globally via sea/air freight.
Company Profile
Wuhan Jlmech Co., Ltd. operates 11 branches across China and serves clients in 30+ countries. Our facilities include a sheet metal workshop, automated coating lines, and rigorous testing labs to meet ISO9001/ISO14001 standards.
Factory After-Sales Service
24/7 technical support, 2-year after-sales support.
Certification
CE, CSA, UL, ISO9001, and ISO14001 certified.
Exhibitions
Featured at PowerGen Asia, Middle East Electricity, and Bauma China.
FAQ
Q: How does temperature affect fuel efficiency?
A: Our generators adapt to -20°C to 50°C, with auto-adjusting fuel systems maintaining consistent consumption across climates.
Q: Can maintenance improve fuel economy?
A: Regular servicing of injectors and filters prevents performance degradation, reducing fuel waste by up to 8%.
Q: Is remote consumption tracking available?
A: Yes—integrated IoT modules offer real-time fuel data visualization for proactive cost management.
Power Your Projects with Confidence
For power systems that prioritize both performance and fuel economy, contact us at skala@whjlmech.com . Discover how JLMECH optimizes the fuel consumption of diesel generator to drive your operational excellence.