Data center diesel unit

AC Output(KW):20KW-2000KW
Rated AC Voltage(V):380
Frequency(HZ):50
Engine Speed(R.P.M):1500
Phase:Three Phase
Type:Silent/Open Frame
Engine Type:4/6 cylinder
Cooling Method: Water Cooling
Starting Method:Electric starting
Customization: OEM/ODM
Certificates: CE/Euro 5/EPA/CARB
Send Inquiry Download
  • Product Description

JLMECH:Your Trusted Data center diesel unit Manufacturer & Supplier

Our Data center diesel unit are engineered for a single purpose: to guarantee absolute, uninterrupted power for your digital infrastructure. Designed as complete, integrated power systems, they provide the foundational reliability required to protect servers, storage, and network equipment from costly downtime and data loss, ensuring 100% operational continuity.

Engineered for Data Center Demands

  • N+1 Redundancy & Instantaneous Response

    • Built for parallel operation, enabling scalable N+1 or 2N redundancy configurations to meet Tier III/IV requirements.

    • Seamless transition with closed-transition automatic transfer switches (ATS) or static switches (STS), ensuring power transfer within seconds without disrupting sensitive loads.

    • Precise synchronization for smooth grid reconnection and load sharing between multiple units.

  • Ultra-Stable, Clean Power Quality

    • Exceptional voltage and frequency regulation (±0.5% and ±0.25% typical) to protect sensitive processor and storage hardware.

    • Extremely low harmonic distortion (<3% THD, often <1% for critical loads) prevents damage to power supplies and UPS systems.

    • High motor starting capacity to support large CRAC/CRAH unit startups without affecting IT bus voltage.

  • Intelligent Management & Infrastructure Integration

    • Advanced controllers with built-in paralleling functionality and compatibility with major DCIM (Data Center Infrastructure Management) and BMS (Building Management System) platforms.

    • Comprehensive remote monitoring, predictive diagnostics, and automated self-testing with detailed reporting.

    • Compact, sound-attenuated designs suitable for urban environments and rooftop installations, with emissions control systems meeting strict local regulations.

Core System Components:

A complete data center power solution typically integrates the diesel generator with an automatic paralleling switchgear, a continuous power monitoring system, and a dedicated cooling design. For primary power applications, units are rated for Prime Power with unlimited run-time; for backup, they are rated as Standby generators.

Data center diesel unit

Specifications

FeatureSpecification
Power Range20–3000 kVA (Prime/Standby)
Noise Level65–75 dB(A) @ 7m (Super Silent Canopy Option)
EngineCummins/Perkins/weichai Turbocharged Engines
AlternatorStamford (IP23 Protection)
Voltage/Frequency220–480V / 50Hz/60Hz (3-Phase Configurable)
Control SystemDeep Sea 7310/8610 with Cloud Remote Monitoring
Fuel Tank8–24 hrs Base Tank + External Tank Support
EmissionsEPA Tier 3 / EU Stage IIIA Compliant

Why Choose US?

  • Fuel Efficiency: 15–30% lower consumption vs. conventional models.

  • Seamless Integration: Pre-wired for ATS compatibility and BIM-ready designs.

  • Durability: 30,000+ hour engine lifecycle (ISO 8528 stress-tested).

Packaging and Delivery

Generator packaging

Data center diesel unit is crated in anti-corrosion wooden frames and shipped globally via air, sea, or land.

Company Profile

Generator factory

With 3 R&D centers, 11 Chinese branches, and 26 overseas offices, Wuhan Jlmech serves clients in 40+ countries.

Factory After-Sales Service

Enjoy 24/7 technical support, on-site maintenance, and spare parts availability within 72 hours.

Certification

Certificate

Our products meet CE, GS, ISO8528, and ISO14001 standards.

Exhibitions

Exhibition

We showcase innovations at global trade fairs like POWER-GEN Asia and Middle East Energy.

FAQ

Q: What is the typical service life?
A: With proper maintenance, minimum operation of 25,000 hours before overhaul.

Q: Can units with different capacities be paralleled?
A: Yes – our generators support parallel operation across rated powers.

Q: Does it offer coastal anti-corrosion protection?
A: Optional marine-grade coating (compliant with ISO 12944 C5-M classification).

Q: What is the maximum operating altitude?
A: No power derating at 3,000 meters altitude; special turbocharging required for 4,500 meters applications.

Q: How often should the coolant be replaced?
A: Every 2,000 hours or 24 months (whichever comes first).

Power Your Projects with Confidence

Whether for emergency backup, construction sites, or data centers, our Data center diesel unit ensures uninterrupted operations. Contact us at skala@whjlmech.com to discuss bulk pricing or custom requirements. Wuhan Jlmech — where innovation meets reliability.