Auto shutoff diesel generators
Rated AC Voltage(V):400
Frequency(HZ):50
Engine Speed(R.P.M):1500
Phase:Three Phase
Type:Silent/Open Frame
Engine Type:3/4/6/8/12/16 cylinder
Cooling Method: Water Cooling
Starting Method:Electric Starting
Customization: OEM/ODM
Certificates: CE/Euro 5/EPA/CARB
- Product Description
JLMECH:Your Trusted Auto shutoff diesel generators Partner
As a specialized manufacturer with advanced technological capabilities in power generation systems, we engineer Auto shutoff diesel generators that provide not just power, but also peace of mind. Our engineering team designs each Auto Shutoff Diesel Generator with a comprehensive sensor network and intelligent controller, enabling it to make critical decisions to protect itself, your investment, and your personnel from catastrophic damage.
Advanced Protection Features of Our Auto shutoff diesel generators
Our Auto shutoff diesel generators incorporates multiple proactive monitoring technologies that deliver unmatched operational safety and asset preservation:
Comprehensive Shutdown Management
Critical Fault Protection: Immediate automatic shutdown in response to low oil pressure, high coolant temperature, or engine overspeed to prevent severe engine damage.
Preventive Safety Shutdown: Triggered by warnings such as low coolant level or high exhaust temperature, preventing minor issues from escalating.
Programmable Operational Timers: Configurable auto-shutdown after a predefined runtime or upon completion of a specific duty cycle, optimizing fuel usage.
Intelligent Monitoring & Sensor Network
Multi-Parameter Real-Time Sensing: Continuous monitoring of oil pressure, coolant temperature, RPM, battery voltage, and output characteristics.
Rapid-Response Control Unit: Processes sensor data in milliseconds to execute a safe shutdown, far exceeding human reaction times.
Diagnostic Fault Logging: Stores detailed event and fault codes in the controller's memory for swift troubleshooting and root cause analysis.
Enhanced Safety & Risk Mitigation
Fire Prevention System: Eliminates the risk of engine overheating, a primary cause of generator-related fires.
Emission Control Safety: Automatically stops the engine in case of aftertreatment system faults or excessive emissions, ensuring environmental compliance.
Electrical Load Protection: Disconnects power and shuts down upon detecting unstable voltage or frequency, safeguarding connected sensitive equipment.

Specifications
| Genset model | Power(kw) | current | Engine model | Cylinders | Bore*stroke | Displacement | Oil capacity | Fuel consumption rate | Dimensionsmm | Gross weight | |
| KW | KVA | A | mm | L | L | g/kw.h | L×W×H | KG | |||
| JL-8GF | 8 | 10 | 14.4 | 403D-11G | 3 | 77*81 | 1.13 | 4.9 | 252 | 1200×700×1100 | 300 |
| JL-11GF | 11 | 13.75 | 19.8 | 403D-15G | 3 | 84*90 | 1.49 | 6.5 | 247 | 1250×700×1100 | 350 |
| JL-16GF | 16 | 20 | 28.8 | 404D-22G | 4 | 84*100 | 2.2 | 11.2 | 245 | 1500×730×1300 | 500 |
| JL-22GF | 22 | 27.5 | 39.6 | 404D-22TG | 4 | 84*100 | 2.2 | 11.2 | 245 | 1600×730×1300 | 550 |
| JL-24GF | 24 | 30 | 43.2 | 1103A-33G | 3 | 105*127 | 3.3 | 8.3 | 211 | 1770×750×1600 | 800 |
| JL-36GF | 36 | 45 | 64.8 | 1103A-33TG1 | 3 | 105*127 | 3.3 | 8.3 | 211 | 2050×750×1600 | 920 |
| JL-48GF | 48 | 60 | 86.4 | 1103A-33TG2 | 3 | 105*127 | 3.3 | 8.3 | 215 | 2200×750×1600 | 1050 |
| JL-52GF | 52 | 65 | 93.6 | 1104A-44TG1 | 4 | 105*127 | 4.4 | 8.3 | 208 | 2250×750×1600 | 1100 |
| JL-64GF | 64 | 80 | 115.2 | 1104A-44TG2 | 4 | 105*127 | 4.4 | 8.3 | 208 | 2300×750×1600 | 1150 |
| JL-80GF | 80 | 100 | 144 | 1104C-44TAG2 | 4 | 100*127 | 4.4 | 8.3 | 208 | 2480×760×1600 | 1250 |
| JL-110GF | 110 | 137.5 | 198 | 1006TAG | 6 | 100*127 | 6 | 19 | 208 | 2600×760×1600 | 1400 |
| JL-120GF | 120 | 150 | 216 | 1006TAG2 | 6 | 100*127 | 6 | 19 | 208 | 2650×760×1600 | 1450 |
| JL-140GF | 140 | 175 | 252 | 1106C-E66TAG4 | 6 | 105*127 | 6.6 | 19 | 205 | 2700×900×1600 | 1700 |
| JL-160GF | 160 | 200 | 288 | 1306C-E87TAG3 | 6 | 116*136 | 8.7 | 26.4 | 201 | 3000×1000×1700 | 2100 |
| JL-180GF | 180 | 225 | 324 | 1306C-E87 TAG4 | 6 | 116*136 | 8.7 | 26.4 | 201 | 3000×1000×1700 | 2100 |
| JL-200GF | 200 | 250 | 360 | 1306C-E87 TAG6 | 6 | 116*136 | 8.7 | 26.4 | 201 | 3100×1000×1700 | 2150 |
| JL-280GF | 280 | 350 | 504 | 2206C-E13TAG2 | 6 | 130*157 | 12.5 | 40 | 209 | 3600×1200×2000 | 3200 |
| JL-320GF | 320 | 400 | 576 | 2206C- E13TAG3 | 6 | 130*157 | 12.5 | 40 | 206 | 3650×1200×2000 | 3300 |
| JL-360GF | 360 | 450 | 648 | 2506C-E15TAG1 | 6 | 137*171 | 15.2 | 53 | 211 | 4000×1200×2100 | 3700 |
| JL-400GF | 400 | 500 | 720 | 2506C-E15TAG2 | 6 | 137*171 | 15.2 | 53 | 211 | 4050×1200×2100 | 3760 |
| JL-480GF | 480 | 600 | 864 | 2806A-E18TAG1A | 6 | 145*183 | 18.1 | 55 | 203 | 4100×1600×2200 | 4600 |
| JL-500GF | 500 | 625 | 900 | 2806A-E18TAG2 | 6 | 145*183 | 18.1 | 55 | 202 | 4200×1600×2200 | 4800 |
| JL-580GF | 580 | 725 | 1044 | 4006-23TAG2A | 6 | 160*190 | 22.9 | 113 | 209 | 4500×1800×2300 | 5500 |
| JL-640GF | 640 | 800 | 1152 | 4006-23TAG3A | 6 | 160*190 | 22.9 | 113 | 209 | 4600×1800×2300 | 6000 |
| JL-720GF | 720 | 900 | 1296 | 4008TAG2A | 8 | 160*190 | 30.5 | 153 | 206 | 4800×2100×2500 | 7700 |
| JL-800GF | 800 | 1000 | 1440 | 4008TAG2A | 8 | 160*190 | 30.5 | 153 | 206 | 4900×2100×2500 | 8000 |
| JL-1000GF | 1000 | 1250 | 1800 | 4012-46TWG2A | 12 | 160*190 | 45.8 | 159 | 212 | 5300×2200×2600 | 10000 |
| JL-1200GF | 1200 | 1500 | 2160 | 4012-46TAG2A | 12 | 160*190 | 45.8 | 159 | 212 | 5400×2200×2600 | 11000 |
| JL-1400GF | 1400 | 1750 | 2520 | 4016TAG | 16 | 160*190 | 61.1 | 214 | 205 | 5700×2800×3100 | 13500 |
| JL-1600GF | 1600 | 2000 | 2880 | 4016TAG2A | 16 | 160*190 | 61.1 | 214 | 208 | 5800×2800×3100 | 14000 |
| JL-1800GF | 1800 | 2250 | 3240 | 4016-61TRG3 | 16 | 160*190 | 61.1 | 214 | 205 | 5900×2800×3100 | 15700 |
The generator sets have a frequency of 50HZ, a rotational speed of 1500rpm, a voltage of 400V, a power factor of 0.8 (lagging), and adopt a three-phase four-wire system. If you need models with other special requirements, please contact us and we will provide the relevant parameters separately.
The Perkins diesel generator set performs outstandingly in terms of emission control. It adopts advanced exhaust gas treatment technologies, such as turbocharging, intercooling technology, and an efficient exhaust gas post-treatment system, which can effectively reduce the emission of harmful substances in the exhaust gas, such as nitrogen oxides (NOx), particulate matter (PM), etc.
Why Choose US?
- Global OEM Expertise: We manufacture for Cummins, MTU, and Perkins, ensuring top-tier quality.
- 2-Year Warranty: Covers mechanical and electrical components.
- Customizable Solutions: Tailor voltage, control panels, or soundproofing to your needs.
- 26 Overseas Offices: Swift technical support in Africa and Southeast Asia.
Packaging and Delivery

Auto shutoff diesel generators are crated in anti-corrosion wooden frames and shipped globally via air, sea, or land.
Company Profile

With 11 branches in China and ISO9001/14001 certifications, Wuhan Jlmech specializes in heavy-duty power solutions trusted by brands like Liebherr and Doosan.
Factory After-Sales Service
Our 24/7 support team provides spare parts, maintenance guides, and on-site troubleshooting.
Certification

CE, ISO8528, and GB/T 2820-97 certified for safety and performance.
Exhibitions

We showcase innovations at global trade shows like Bauma China and PowerGen Africa.
FAQ
Q: What's the lead time for bulk orders?
A: 15-30 days, depending on customization.
Q: Do you provide installation training?
A: Absolutely—free manuals and virtual/physical training sessions.
Trusted by Global Industries
From powering Nigerian hospitals to Indonesian data centers, our Auto shutoff diesel generators are the backbone of reliable operations. Need a quote or technical details? Contact our team at skala@whjlmech.com — we're here to keep your business running!












